Socket Mobile Ethernet Blaster Communications Cable Manuel d'utilisateur Page 31

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 30
Altera Corporation 3–5
December 2004 EthernetBlaster Communications Cable User Guide
EthernetBlaster Communications Cable User Guide
References
For more information on configuration and in-system programmability
(ISP), see the following sources:
AN 39: IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera Devices
AN 95: In-System Programmability in MAX Devices
“Configuring Cyclone FPGAs” chapter in the Cyclone Device
Handbook
“Configuring Cyclone II Devices” chapter in the Cyclone II Device
Handbook
Configuring Stratix II Devices” chapter in Volume 2 of the Stratix II
Device Handbook
Configuring Stratix and Stratix GX Devices” chapter in the Stratix
Device Handbook
“In-System Programmability Guidelines for MAX II Devices”
chapter in the MAX II Device Handbook
Serial Configuration Devices Data Sheet
“Programming & Configuration” chapter in the Introduction to
Quartus II manual
The Programming module of the Quartus II online tutorial
Refer to the following glossary definitions in Quartus II Help:
“EthernetBlaster Cable” (general description)
“Configuration scheme” (general description)
“Programming files” (general description)
Table 3–5. EthernetBlaster Cable DC Operating Conditions
Symbol Parameter Conditions Min Max Unit
V
IH
High-level input voltage V
CC(TARGET)
< or = 3.3 V
V
CC(TARGET)
–0.2 V
High-level input voltage V
CC(TARGET)
> 3.3 V
3.1 V
V
IL
Low-level input voltage
0.15 V
V
OH
5.0-V high-level output voltage V
CC(TARGET)
= 4.5 V, I
OH
=20µA
3.3 V
3.3-V high-level output voltage V
CC(TARGET)
= 3.0 V, I
OH
=20µA
2.0 V
2.5-V high-level output voltage V
CC(TARGET)
= 2.375 V, I
OH
=20µA
1.6 V
1.8-V high-level output voltage V
CC(TARGET)
= 1.71 V, I
OH
=20µA
1.15 V
1.5-V high-level output voltage V
CC(TARGET)
= 1.43 V, I
OH
=20µA
0.95 V
V
OL
5.0-V low-level output voltage V
CC(TARGET)
= 5.5 V, I
OL
=1mA
0.4 V
3.3-V low-level output voltage V
CC(TARGET)
= 3.6 V, I
OL
=1mA
0.4 V
2.5-V low-level output voltage V
CC(TARGET)
= 2.625 V, I
OL
=1mA
0.4 V
1.8-V low-level output voltage V
CC(TARGET)
= 1.89 V, I
OL
=1mA
0.4 V
1.5-V low-level output voltage V
CC(TARGET)
= 1.57 V, I
OL
=1 mA
0.4 V
I
CC(SYS)
Operating current (No Load) Typical I
CC(SYS)
= 350mA @ V
CC(SYS)
= 12V
700 mA